Hydraulic Breaker

Specifications

Model Fxj 175 Fxj 275 Fxj 375 Fxj 475
Body Weight (incl. Rod) 560 kg 940 kg 1,295 kg 1,630 kg
Operating weight V-Box type 960 kg 1,705 kg 2,445 kg 3,100 kg
Height (V-Box) 2,288 mm 2,796 mm 3,155 mm 3,372 mm
Impact rate 450 ~ 600 min-1 350 ~ 550 min-1 300 ~ 450 min-1 250 ~ 350 min-1
Oil flow rate 100 ~ 160 L/min 145 ~ 220 L/min 170 ~ 260 L/min 200 ~ 300 L/min
Operating oil pressure 16 ~ 18 MPa 16 ~ 18 MPa 16 ~ 18 MPa 16 ~ 18 MPa
Hose diameter (IN/OUT) 19 / 19 mm 25 / 25 mm 25 / 25 mm 32 / 32 mm
Rod diameter Ф 120 mm Ф 140 mm Ф 155 mm Ф 170 mm
Weight of base machine 12 ~ 20 ton 19 ~ 30 ton 25 ~ 40 ton 35 ~ 55 ton

 

 

Model   Fx15 ∝ Side plate Fx25 ∝ T-Box Fx35 ∝ T-Box Fx45 ∝ T-Box Fx55 ∝ T-Box
Body Weight (incl. Rod) kg 36 56 80 110 150
OPERATING WEIGHT
Side plate kg 60 83 129 165 220
T-Box incl. Top bracket kg - 118 157 208 281
ST-Box incl. Top bracket kg - 118 167 220 292
HEIGHT
Side plate mm 924 1,030 1,172 1,285 1,388
T-Bx incl. Top bracket mm - 1,209 1,209 1,342 1,440
WIDTH
Side plate mm 180 180 214 214 235
T-Box incl Top bracket mm - 180 214 235 235
Impact rate min-1 600 - 1,500 600 - 1,500 600 - 1,300 600 - 1,100 500 - 1,100
Oil flow rate ℓ/min 10 - 28 18 - 35 24 - 52 30 - 60 40 - 85
Operating oil pressure MPa 10 - 14 10 - 14 12 - 16 12 - 16 12 - 16
Rod diameter mm 36 45 52 60 68
Hose diameter mm 9 12 12 12 12
Weight of base machine ton 0.85 - 1.5 1.35 - 2.5 1.9 - 3.5 3.0 - 4.5 4.0 - 5.5

 

NUMBER ONE in breaking power among this class of breakers, delivering 10-20% more blow power than conventional models, they also deliver an added degree of high reliability.

Reduced maintenance costs, and added new functions

  • Provided with a safety valve as standard
  • Dust intake prevention device provided as standard
  • Piston idle blow prevention device (optional)
  • “Auto-grease” lubricating device (optional)

“Built-in type multi-functioning design” respond to all types of “needs” on “job-sites”

  • Number-of-blows adjustment function (manual) …
  • Standard (remote control) … (optional)
  • Tunnel / underwater specifications … (Optional)